Legrand / Raritan / Server Technology Xerus™ JSON-RPC API
|
Specification of a Sensor. More...
import <GatewaySensorManager.idl;
Public Attributes | |
| string | sensorId |
| Unique sensor id, is automatically generated if not set. | |
| boolean | disabled |
| Set disabled = true prevents any usage of the specification. | |
| string | deviceId |
| remote device id | |
| string | classId |
| sensor class id | |
| string | encodingId |
| sensor encoding id | |
| string | defaultName |
| sensor name | |
| string | defaultDescription |
| sensor description | |
| string | defaultLocationX |
| sensor location X coordinate | |
| string | defaultLocationY |
| sensor location Y coordinate | |
| string | defaultLocationZ |
| sensor location Z coordinate | |
Specification of a Sensor.
Definition at line 590 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::classId |
sensor class id
classId is used to locate the corresponding SensorClass. classId = "" prevents the sensor specification from being used for an imported gateway sensor. The sensor value is read anyway, and a read error or a interpretation as Interpretation::REJECT_DEVICE prevents the successful detection of the device
Definition at line 618 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::defaultDescription |
sensor description
defaultDescription is used as default sensor slot description
Definition at line 639 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::defaultLocationX |
sensor location X coordinate
defaultLocationX is used as default sensor slot location X coordinate
Definition at line 646 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::defaultLocationY |
sensor location Y coordinate
defaultLocationY is used as default sensor slot location Y coordinate
Definition at line 653 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::defaultLocationZ |
sensor location Z coordinate
defaultLocationZ is used as default sensor slot location Z coordinate
Definition at line 660 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::defaultName |
sensor name
defaultName is used as default sensor slot name
Definition at line 632 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::deviceId |
remote device id
deviceId is used to locate the corresponding RemoteDevice that provides the physical sensor
Definition at line 607 of file GatewaySensorManager.idl.
| boolean peripheral::GatewaySensorManager::Sensor::disabled |
Set disabled = true prevents any usage of the specification.
Definition at line 599 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::encodingId |
sensor encoding id
classId is used to locate the corresponding ValueEncoding
Definition at line 625 of file GatewaySensorManager.idl.
| string peripheral::GatewaySensorManager::Sensor::sensorId |
Unique sensor id, is automatically generated if not set.
Definition at line 594 of file GatewaySensorManager.idl.